default-network-drivers() source options
The systemd-journal()
driver has the following options.
ca-dir()
Accepted values: | Directory name |
Default: | none |
Description: The name of a directory that contains a set of trusted CA certificates in PEM format. The CA certificate files have to be named after the 32-bit hash of the subject’s name. This naming can be created using the c_rehash utility in openssl. For an example, see Configuring TLS on the AxoSyslog clients. The AxoSyslog application uses the CA certificates in this directory to validate the certificate of the peer.
This option can be used together with the optional ca-file()
option.
ca-file()
Accepted values: | File name |
Default: | empty |
Description: Optional. The name of a file that contains a set of trusted CA certificates in PEM format. The AxoSyslog application uses the CA certificates in this file to validate the certificate of the peer.
Example format in configuration:
ca-file("/etc/pki/tls/certs/ca-bundle.crt")
ca-file()
option can be used together with the ca-dir()
option, and it is relevant when peer-verify()
is set to other than no
or optional-untrusted
.
flags()
Type: | assume-utf8, dont-store-legacy-msghdr, empty-lines, expect-hostname, kernel, no-hostname, no-multi-line, no-parse, sanitize-utf8, store-legacy-msghdr, store-raw-message, syslog-protocol, validate-utf8 |
Default: | empty set |
Description: Specifies the log parsing options of the source.
-
assume-utf8: The
assume-utf8
flag assumes that the incoming messages are UTF-8 encoded, but does not verify the encoding. If you explicitly want to validate the UTF-8 encoding of the incoming message, use thevalidate-utf8
flag. -
dont-store-legacy-msghdr: By default, AxoSyslog stores the original incoming header of the log message. This is useful if the original format of a non-syslog-compliant message must be retained (AxoSyslog automatically corrects minor header errors, for example, adds a whitespace before
msg
in the following message:Jan 22 10:06:11 host program:msg
). If you do not want to store the original header of the message, enable thedont-store-legacy-msghdr
flag. -
empty-lines: Use the
empty-lines
flag to keep the empty lines of the messages. By default, AxoSyslog removes empty lines automatically. -
exit-on-eof: If this flag is set on a source, AxoSyslog stops when an EOF (end of file) is received. Available in version 4.9 and later.
-
expect-hostname: If the
expect-hostname
flag is enabled, AxoSyslog will assume that the log message contains a hostname and parse the message accordingly. This is the default behavior for TCP sources. Note that pipe sources use theno-hostname
flag by default. -
guess-timezone: Attempt to guess the timezone of the message if this information is not available in the message. Works when the incoming message stream is close to real time, and the timezone information is missing from the timestamp.
-
kernel: The
kernel
flag makes the source default to theLOG_KERN | LOG_NOTICE
priority if not specified otherwise. -
no-header: The
no-header
flag triggers AxoSyslog to parse only thePRI
field of incoming messages, and put the rest of the message contents into$MSG
.Its functionality is similar to that of the
no-parse
flag, except theno-header
flag does not skip thePRI
field.Note Essentially, theno-header
flag signals AxoSyslog that thesyslog
header is not present (or does not adhere to the conventions / RFCs), so the entire message (except from thePRI
field) is put into$MSG
.Example: using the no-header flag with the syslog-parser() parser
The following example illustrates using the
no-header
flag with thesyslog-parser()
parser:parser p_syslog { syslog-parser( flags(no-header) ); };
-
no-hostname: Enable the
no-hostname
flag if the log message does not include the hostname of the sender host. That way AxoSyslog assumes that the first part of the message header is ${PROGRAM} instead of ${HOST}. For example:source s_dell { network( port(2000) flags(no-hostname) ); };
-
no-multi-line: The
no-multi-line
flag disables line-breaking in the messages: the entire message is converted to a single line. Note that this happens only if the underlying transport method actually supports multi-line messages. Currently thefile()
andpipe()
drivers support multi-line messages. -
no-parse: By default, AxoSyslog parses incoming messages as syslog messages. The
no-parse
flag completely disables syslog message parsing and processes the complete line as the message part of a syslog message. The AxoSyslog application will generate a new syslog header (timestamp, host, and so on) automatically and put the entire incoming message into the MESSAGE part of the syslog message (available using the${MESSAGE}
macro). This flag is useful for parsing messages not complying to the syslog format.If you are using the
flags(no-parse)
option, then syslog message parsing is completely disabled, and the entire incoming message is treated as the ${MESSAGE} part of a syslog message. In this case, AxoSyslog generates a new syslog header (timestamp, host, and so on) automatically. Note that even thoughflags(no-parse)
disables message parsing, some flags can still be used, for example, theno-multi-line
flag. -
sanitize-utf8: When using the
sanitize-utf8
flag, AxoSyslog converts non-UTF-8 input to an escaped form, which is valid UTF-8.Prior to version 4.6, this flag worked only when parsing RFC3164 messages. Starting with version 4.6, it works also for RFC5424 and raw messages.
-
store-legacy-msghdr: By default, AxoSyslog stores the original incoming header of the log message, so this flag is active. To disable it, use the
dont-store-legacy-msghdr
flag. -
store-raw-message: Save the original message as received from the client in the
${RAWMSG}
macro. You can forward this raw message in its original form to another AxoSyslog node using thesyslog-ng()
destination, or to a SIEM system, ensuring that the SIEM can process it. Available only in 3.16 and later. -
syslog-protocol: The
syslog-protocol
flag specifies that incoming messages are expected to be formatted according to the new IETF syslog protocol standard (RFC5424), but without the frame header. Note that this flag is not needed for thesyslog
driver, which handles only messages that have a frame header. -
validate-utf8: The
validate-utf8
flag enables encoding-verification for messages.Prior to version 4.6, this flag worked only when parsing RFC3164 messages. Starting with version 4.6, it works also for RFC5424 and raw messages.
For RFC5424-formatted messages, if the BOM character is missing, but the message is otherwise UTF-8 compliant, AxoSyslog automatically adds the BOM character to the message.
The byte order mark (BOM) is a Unicode character used to signal the byte-order of the message text.
log-iw-size()
Type: | number |
Default: | 100 |
Description: The size of the initial window, this value is used during flow-control. Its value cannot be lower than 100, unless the dynamic-window-size()
option is enabled. For details on flow-control, see Managing incoming and outgoing messages with flow-control.
log-msg-size()
Type: | number (bytes) |
Default: | Use the global log-msg-size() option, which defaults to 65536 (64 KiB). |
Description: Maximum length of an incoming message in bytes. This length includes the entire message (the data structure and individual fields). The maximal value that can be set is 268435456 bytes (256 MiB).
For messages using the IETF-syslog message format (RFC5424), the maximal size of the value of an SDATA field is 64 KiB.
log-msg-size()
does not need to be set higher than 10 MiB.
For details on how encoding affects the size of the message, see Message size and encoding.
You can use human-readable units when setting configuration options. For details, seeNotes about the configuration syntax.
Uses the value of the global option if not specified.
max-connections()
Type: | number |
Default: | 10 |
Description: Specifies the maximum number of simultaneous connections.
Note that the total number of connections the default-network-drivers()
source can use is 3*max-connections()
, because this value applies to the network(tcp)
, syslog(tcp)
, and syslog(tls)
connections individually.
rfc5424-tcp-port()
Type: | number |
Default: | 601 |
Description: The TCP port number where the default-network-drivers()
source receives RFC5424-formatted (IETF-syslog) messages.
rfc5424-tls-port()
Type: | number |
Default: | 6514 |
Description: The TCP port number where the default-network-drivers()
source receives RFC5424-formatted (IETF-syslog), TLS-encrypted messages.
To receive messages using a TLS-encrypted connection, you must set the tls(key-file() cert-file())
options of the default-network-drivers()
source. For example:
source s_network {
default-network-drivers(
tls(
key-file("/path/to/ssl-private-key")
cert-file("/path/to/ssl-cert")
)
);
};
tcp-port()
Type: | number |
Default: | 514 |
Description: The TCP port number where the default-network-drivers()
source receives RFC3164-formatted (BSD-syslog) messages.
tls()
Type: | tls options |
Default: | n/a |
Description: This option sets various options related to TLS encryption, for example, key/certificate files and trusted CA locations. TLS can be used only with tcp-based transport protocols. For details, see TLS options.
udp-port()
Type: | number |
Default: | 514 |
Description: The UDP port number where the default-network-drivers()
source receives RFC3164-formatted (BSD-syslog) messages.